16 photos from ORACLE Lighting. Select the photo to enlarge it.
ORACLE Lighting · Part # 5769-332
ORACLE Lighting 7" High Powered LED Headlights - Black Bezel - Dynamic ColorSHIFT - Jeep Wrangler JK
Email for price
Fits: Chevrolet Bel Air 1955-1957; Chevrolet Blazer 1969-1974; Chevrolet C10 Pickup 1960-1974 and 47 more (full list below)
Email for price. ORACLE is running a sale on its own store right now, so we quote this part by email: tell us the part and your ZIP code and we reply with a delivered price before you pay.
Ships from ORACLE Lighting in Metairie, Louisiana. We order it from ORACLE when you place your order; ORACLE states that most items ship within 1-2 business days unless out of stock (pre-assembled lights after ORACLE's 3-5 business day build), and we email you the tracking. Your card is only charged after the supplier confirms the part. Stock shown is ORACLE's (checked November 8, 2026); we confirm it with ORACLE before charging your card.
Notice: Warning: This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm. For more information: www.P65Warnings.ca.gov
Description
Product Description
Features
What's Included
Installation
ORACLE Part# 5769-332
The Ultimate LED replacement Halo Headlight for the Jeep Wrangler JK NOW with Dynamic ColorSHIFT® Technology! The new ORACLE Lighting Dynamic ColorSHIFT® Halos feature individually addressable LEDs which pack a ton of unique features.. The Dynamic features allow the user to run multiple moving color patterns through the LEDs, creating a vivid eye-catching lighting effect.
Complete Package for adding High-Performance 7" LED Headlights to your Wrangler JK without any fabrication or cutting your factory wiring. This complete Plug-&-Play kit also features Vertical and Horizontal headlight adjustment so you can put the light on the road (where you need it) and not blind oncoming traffic.
This rugged solid-state LED design is perfect for the Jeep owner looking for high-quality lighting for better night time visibility without overpaying. Installation is very easy with the included JK specific "Plug and Play" connectors. You can even choose optional colored Halos for even more customization!
Latest Product Improvement
• Improvements in brightness and reliability by adding a constant current LED driver to the main circuit board inside of the lamp to control the halos. • NEW! No need for Anti-Flicker Wiring Adapters- The new SMART Integrated Can-Bus system automatically adjusts- preventing flicker issues. • Increased Reliability- By conditioning the power going into the LEDs this prevents degradation which can shorten the overall lifespan of the product. • Wider Input Voltage Range- The new SMD Halos can operate on a very wide voltage range from 12V-24V so that voltage spike can not damage the LEDs. • Brighter LED Halos- by moving the heat load of the resistors off the PCB we are able to increase the number of LEDs on the circuit board without thermal issues. • LED chips upgraded from a Cree LED to a Phillips Luxeon ZES chip. They deliver a very high efficacy 130LM/W ratio while having lower thermal output.
Product Features: (Per Light) • Low Beam Wattage: 30W Normal/36W Max • Low Beam Lumens: 2200 Lumens/3600 Raw Lumens • High Beam Wattage: 40W Normal/48W Max • High Beam Lumens: 3600 Lumens/4800 Raw Lumens • Color Temperature: 6000K (Cool White Color) • Input Voltage of Light: 12-24V DC • Input Voltage of Halo (If Included): 12V DC • Current Draw: 2.50 Amps @ 12V DC / 1.30 Amps @ 24V DC • ORACLE Dynamic ColorSHIFT Halo Rings Pre-Installed • Premium Performance Phillips Luxeon ZES LEDs • Die-Cast Housing with Corrosion Resistant Coating • Heavy Duty Solid State Electronics • Hard-coated Polycarbonate Lens • Wide Beam Pattern with Sharp Cut-Off Line • Easy Plug & Play Installation • 2 Year Warranty • DOT and SAE Certified • Connect wires directly to the included Dynamic ColorSHIFT Hub.
(2) 7" High Powered LED Headlights - Black Bezel - Dynamic ColorSHIFT® - Jeep Wrangler JK
App Control: (Download App "RGB Lights") Through the App you can easily make standard white colors as well as any static colors using the LED color wheel. What makes these DYNAMIC halos more unique is that you can also display a variety of moving patterns within the app. With over 200 different patterns there is something to fit every color scheme you can imagine!
Photos, product description, specifications, install guides and fitment from ORACLE Lighting (oraclelights.com and ORACLE's dealer product data). Sold by RR Motor Services LLC, an authorized ORACLE Lighting dealer.
How to use
5769-332 Instructions
ORACLE's installation picture, shown as published.
5769-332 Instructions: pages with pictures (1)Page 1 of 1
ORACLE's installation picture, shown as published.
ORACLE Dynamic 5769-332 Instructions update 9afd65be-5c89-4eb3-b7c8-86df6115e396: pages with pictures (1)Page 1 of 1
5769 instructions 2019
ORACLE's installation picture, shown as published.
5769 instructions 2019: pages with pictures (1)Page 1 of 1
View FMVSS 108 Test Report
ORACLE's installation guide (38 pages), shown as printed with its pictures and diagrams.
View FMVSS 108 Test Report: pages with pictures (38)Page 1 of 38Page 2 of 38Page 3 of 38Page 4 of 38Page 5 of 38Page 6 of 38Page 7 of 38Page 8 of 38Page 9 of 38Page 10 of 38Page 11 of 38Page 12 of 38Page 13 of 38Page 14 of 38Page 15 of 38Page 16 of 38Page 17 of 38Page 18 of 38Page 19 of 38Page 20 of 38Page 21 of 38Page 22 of 38Page 23 of 38Page 24 of 38Page 25 of 38Page 26 of 38Page 27 of 38Page 28 of 38Page 29 of 38Page 30 of 38Page 31 of 38Page 32 of 38Page 33 of 38Page 34 of 38Page 35 of 38Page 36 of 38Page 37 of 38Page 38 of 38Text of this guide
Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC SAFETY COMPLIANCE TESTING FOR FMVSS 108 Lamps, Reflective Devices, and Associated Equipment * * * * * * * * * * * * * * * * * * * * * * * * ISOQA Technical Service Co., Ltd. 60, Yong Long Road, Da-Li, Taichung, 41257 Taiwan FINAL REPORT - This report becomes effective when the signatory signs it and affixed the seal to the document. - No part of this report may be altered and may not be reproduced except in full without the written approval of the test laboratory. - The specification and basic data of this test report are provided by the applicant. The applicant shall be responsible for it if the information provided is incorrect and effects the test results. - The test results only apply to the test sample(s) received. - The test samples are selected and provided by the applicant or manufacturer. The laboratory does not responsible for implement sampling. - The decision rule is inherent in the requested specification or standard, a further consideration of the level of risk and MU is not necessary. 2024-03-01 Signature of Responsible Laboratory Official Approval Date Title: Laboratory Manager Cover Page P:\client\AAC Enterprises LLC\23-0739_5769-123\108-ISOQA-23-0739_5769-123_Final Report page 1 of 38 Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC TABLE OF CONTENTS Number of page Contents in each report Cover Page 1 Contents 1 Product information 1 Front Turn Signal Lamp 6 Parking Lamp 6 Headlamp - Lower Beam 21 Headlamp - Upper Beam Drawing 1 Revision History 1 0 0 0 Total Pages 38 Report Prepared By : Jenny Zhou Review By : Arthur Chang Approval By : Julie Wu Contents P:\client\AAC Enterprises LLC\23-0739_5769-123\108-ISOQA-23-0739_5769-123_Final Report page 2 of 38 Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC PRODUCT INFORMATION Test Component 5769-123 AAC Enterprises LLC Applicant 4401 Division St. Metairie,LA 70002,0, USA Trade Mark ORACLE Lens Material Covestro Makrolon AL2447 Polycarbonate 550012 Clear # Coating of Exterior Lens UVHC 3000 Inner Lens Material Covestro Makrolon AL2447 Polycarbonate 550012 Clear # Reflex Reflector Material --- Applicable Vehicle on Motor Vehicles Rated Voltage 12 V Marking on Lens (Trade mark) DOT SAE VOR HL P I5 5769-123 24 Marking on Housing 12V Method of Mounting to Vehicle bolted * Above-mentioned information is provided by the applicant ('---' = not applicable or no information provided) Front Turn Signal Headlamp - Lower Headlamp - Upper Functions Parking Lamp Lamp Beam Beam Requirements FMVSS 108 FMVSS 108 FMVSS 108 FMVSS 108 SAE Standards for Reference SAE J588 SAE J222 --- --- Identification Code of SAE J759 I5 P HL HL Number of Compartments or Lamps 1 1 1 1 Color of External Lens Clear Clear Clear Clear Color of Inner Lens or Filter Clear Clear Clear Clear Color of Light Emitted Yellow White White White Light Source Designation LED × 72 LED × 72 LED × 6 LED × 9 Design Voltage 12.8 V 12.8 V 12.8 V 12.8 V Rated Mean Spherical Candlepower N/A N/A N/A N/A Effective projected illuminated area of lens (mm2) 3200 N/A N/A N/A Method of determination Projected N/A N/A N/A Test Item Inspector Date Number of Tested Physical Inspection Tan Liao 2024/1/19 2 2 2 2 Photometry Test Tan Liao 2024/1/19 2 2 2 2 Color Test Tan Liao 2024/1/19 2 2 2 2 Moisture Test John Lai 2024/2/6 1 1 1 1 Corrosion Test Elton Li 2023/9/28 1 1 1 1 Vibration Test Elton Li 2023/9/26 1 1 1 1 Dust Test John Lai 2024/2/2 1 1 1 1 Abrasion Test John Lai 2024/2/5 --- --- 1 1 Chemical Resistance John Lai 2024/2/5 --- --- 1 1 Test Temp. Cycle Test John Lai 2024/2/16 --- --- 1 1 Internal Heat Test John Lai 2024/2/16 --- --- 1 1 Humidity Test John Lai 2024/2/20 --- --- 1 1 Product Information P:\client\AAC Enterprises LLC\23-0739_5769-123\108-ISOQA-23-0739_5769-123_Final Report page 3 of 38 Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC TURN SIGNAL LAMP TEST REPORT Test Component 5769-123 Applicant AAC Enterprises LLC Test Laboratory ISOQA Technical Service Co., Ltd. Test Date 2023/9/26 - 2024/2/20 Report Number 108-ISOQA-23-0739 Number of devices tested See below Light source Designation LED × 72 SUMMARY Test Results Test Description Number Passed Number Failed - Physical Inspection 2 - - Photometry Test 2 - - Color Test 2 - - Dust Test 1 - - Moisture Test 1 - - Corrosion Test 1 - - Vibration Test 1 - Remarks : Signature of Responsible Laboratory Official Title : Laboratory Manager Date: : March 1, 2024 Turn Signal Lamp P:\client\AAC Enterprises LLC\23-0739_5769-123\108-ISOQA-23-0739_5769-123_Final Report page 4 of 38 Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC PHYSICAL INSPECTION Inspection Performed by : Tan Liao Date : 2024/1/19 Marking on Lens (Trade mark) DOT SAE VOR HL P I5 5769-123 24 Marking on Housing 12V Lens Material Covestro Makrolon AL2447 Polycarbonate 550012 Clear # Coating of External Lens UVHC 3000 Trade No/ Designation LED Light Sources Used Quantity 72 Rated Voltage 12 V Remarks : EFFECTIVE PROJECTED LUMINOUS LENS AREA Test Performed by : Tan Liao Date : 2024/1/19 Passenger cars, multipurpose passenger vehicles, trucks, trailers, and buses Vehicle Type of less than 2032 mm in overall width Method of determination Projected Effective projected illuminated area of Requirement Value Result lens (mm2) 2200 3200 PASSED Remarks : Turn Signal Lamp P:\client\AAC Enterprises LLC\23-0739_5769-123\108-ISOQA-23-0739_5769-123_Final Report page 5 of 38 Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC PHOTOMETRY TEST Test Performed by : Tan Liao Date : 2024/1/19 Test distance(m) : 3.182 m Light Source Designation : LED × 72 Tested Voltage : 12.8 V Lighted Sections : 3 Sample 1 Sample 2 Steady Burning at H-V 1 min. Steady Ratio 1 min. Steady Ratio (according to SAE J1889) 1452.000 1150.000 1.263 1515.000 1177.000 1.287 Rto. Sample 1 Sample 2 Minimum Maximum Test Points Zone Parking (cd) (cd) Rto Measured (1) Rto Measured (1) Lamp 5U - 20L 1 3 87.5 - 33.5 504.900 35.7 532.900 5D - 20L 1 - 87.5 - 38.0 509.000 37.2 527.300 10U - 5L 1 3 137.5 - 53.4 900.000 51.2 928.000 10D - 5L 1 - 137.5 - 58.4 896.000 49.7 834.000 5U - 10L 2 3 250 - 54.2 912.000 51.7 934.000 H - 10L 2 3 350 - 57.6 1001.000 53.8 994.000 5D - 10L 2 - 250 - 56.1 931.000 54.2 959.000 5U - V 3 5 587.5 - 58.1 1128.000 57.6 1132.000 H - 5L 3 5 687.5 - 59.8 1096.000 58.6 1136.000 H-V 3 5 687.5 - 62.7 1150.000 61.9 1177.000 H - 5R 3 5 687.5 - 60.5 1106.000 59.9 1150.000 5D - V 3 - 587.5 - 60.6 1103.000 60.4 1116.000 5U - 10R 4 3 250 - 54.5 976.000 52.3 972.000 H - 10R 4 3 350 - 57.4 1024.000 54.7 1030.000 5D - 10R 4 - 250 - 57.7 999.000 54.2 971.000 10U - 5R 5 3 137.5 - 52.5 909.000 50.9 932.000 10D - 5R 5 - 137.5 - 57.6 878.000 55.7 941.000 5U - 20R 5 3 87.5 - 36.5 539.000 33.7 501.300 5D - 20R 5 - 87.5 - 39.9 546.500 35.1 484.400 Visibility 0.3 - - (0.814) - (0.883) Zone Total Luminous Intensity Zone Minimum (cd) Sample 1 Sample 2 1 450 2809.900 2822.200 2 850 2844.000 2887.000 3 3237.5 5583.000 5711.000 4 850 2999.000 2973.000 5 450 2872.500 2858.700 (1) The measured values at each individual test point shall not be less than 60% of the required minimum value shown for that individual test point location. The sum of the luminous intensity measurements at each test point within a zone shall not be less than the Zone Total Luminous Intensity shown. Turn Signal Lamp P:\client\AAC Enterprises LLC\23-0739_5769-123\108-ISOQA-23-0739_5769-123_Final Report page 6 of 38 Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC COLOR TEST Test Performed by : Tan Liao Date : 2024/1/19 Test distance(m) : 3.182 m Light Source Designation : LED × 72 Color of Light Emitted : Yellow Sample 1 Sample 2 Color emitted from HV point x= 0.5990 0.5953 y= 0.3999 0.4032 0.45 0.44 0.43 0.42 S1 0.41 S2 0.4 0.39 0.38 0.54 0.55 0.56 0.57 0.58 0.59 0.6 0.61 0.62 Remarks : Turn Signal Lamp P:\client\AAC Enterprises LLC\23-0739_5769-123\108-ISOQA-23-0739_5769-123_Final Report page 7 of 38 Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC MOISTURE TEST Inspection Performed by : John Lai Date : 2024/2/6 Requirement Yes No The device(s) accumulated less than 2 cc of moisture. x Necessary to rephotometer test x Additional photometric data sheet added to report x Remarks : DUST TEST Inspection Performed by : John Lai Date : 2024/2/2 Requirement Yes No At completion of test, the maximum candlepower of the device(s) was within x 10% of those prior to Dust Test. Necessary to rephotometer test x Additional photometric data sheet added to report x Before the Test After the Test Ratio Maximum photometric intensity (cd) 1150.000 1106.000 3.8% Remarks : Turn Signal Lamp P:\client\AAC Enterprises LLC\23-0739_5769-123\108-ISOQA-23-0739_5769-123_Final Report page 8 of 38 Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC CORROSION TEST Inspection Performed by : Elton Li Date : 2023/9/28 Requirement Yes No The device(s) completed the test without evidence of corrosion which could x impair proper functioning of the device(s). Necessary to rephotometer test x Additional photometric data sheet added to report x Remarks : Turn Signal Lamp P:\client\AAC Enterprises LLC\23-0739_5769-123\108-ISOQA-23-0739_5769-123_Final Report page 9 of 38 Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC PARKING LAMP TEST REPORT Test Component 5769-123 Applicant AAC Enterprises LLC Test Laboratory ISOQA Technical Service Co., Ltd. Test Date 2023/9/26 - 2024/2/20 Report Number 108-ISOQA-23-0739 Number of devices tested See below Light source Designation LED × 72 SUMMARY Test Results Test Description Number Passed Number Failed - Physical Inspection 2 - - Photometry Test 2 - - Color Test 2 - - Dust Test 1 - - Moisture Test 1 - - Corrosion Test 1 - - Vibration Test 1 - Remarks : Signature of Responsible Laboratory Official Title : Laboratory Manager Date: : March 1, 2024 Parking Lamp P:\client\AAC Enterprises LLC\23-0739_5769-123\108-ISOQA-23-0739_5769-123_Final Report page 10 of 38 Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC PHYSICAL INSPECTION Inspection Performed by : Tan Liao Date : 2024/1/19 Marking on Lens (Trade mark) DOT SAE VOR HL P I5 5769-123 24 Marking on Housing 12V Lens Material Covestro Makrolon AL2447 Polycarbonate 550012 Clear # Coating of External Lens UVHC 3000 Trade No/ Designation LED Light Sources Used Quantity 72 Rated Voltage 12 V Remarks : Parking Lamp P:\client\AAC Enterprises LLC\23-0739_5769-123\108-ISOQA-23-0739_5769-123_Final Report page 11 of 38 Report No. : 108-ISOQA-23-0739 Rev. : 00 Test Component : 5769-123 www.isoqa.org | isoqa@isoqa.org Applicant : AAC Enterprises LLC PHOTOMETRY TEST Test Performed by : Tan Liao Date : 2024/1/19 Test distance(m) : 3.182 m Light Source Designation : LED × 72 Tested Voltage : 12.8 V Sample 1 Sample 2 Steady Burning at H-V 1 min. Steady Ratio 1 min. Steady Ratio (according to SAE J1889) 18.460 18.340 1.007 19.210 19.010 1.011 Minimum Maximum Sample 1 Sample 2 Test Points Zone (cd) (cd) Measured (1) Measured (1) 5U - 20L 1 0.4 125 15.090 14.920 5D - 20L 1 0.4 250 13.400 14.170 10U - 5L 1 0.8 125 16.840 18.140 10D - 5L 1 0.8 250 15.340 16.770 5U - 10L 2 0.8 125 16.840 18.070 H -
ORACLE Dynamic 5769-332 Instructions update
ORACLE's installation picture, shown as published.
ORACLE Dynamic 5769-332 Instructions update: pages with pictures (1)Page 1 of 1
How-to instructions and step photos from ORACLE Lighting.